checkCIF (full publication check) running



Checking for embedded fcf data in CIF ...
Found embedded fcf data in CIF. Extracting fcf data from uploaded CIF, please wait . . . . .

checkCIF/PLATON (full publication check)


Structure factors have been supplied for datablock(s) AC_0004Y

THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED CRYSTALLOGRAPHIC REFEREE.
No syntax errors found. CIF dictionary
Please wait while processing .... Interpreting this report
Structure factor report

Datablock: AC_0004Y
Bond precision: C-C = 0.0041 A Wavelength=0.71073
Cell: a=10.8324(7) b=17.5137(12) c=18.6140(12)
alpha=93.320(3) beta=101.013(3) gamma=103.885(3)
Temperature: 100 K
Calculated Reported
Volume 3345.0(4) 3345.0(4)
Space group P -1 P -1
Hall group -P 1 -P 1
Moiety formula C68 H50 F18 O16 Y2 C68 H50 F18 O16 Y2
Sum formula C68 H50 F18 O16 Y2 C68 H50 F18 O16 Y2
Mr 1642.90 1642.90
Dx,g cm-3 1.631 1.631
Z 2 2
Mu (mm-1) 1.845 1.845
F000 1652.0 1652.0
F000' 1642.03
h,k,lmax 13,21,23 13,21,22
Nref 13276 13202
Tmin,Tmax 0.856,0.929 0.837,0.942
Tmin' 0.832
Correction method= # Reported T Limits: Tmin=0.837 Tmax=0.942 AbsCorr = MULTI-SCAN
Data completeness= 0.994 Theta(max)= 26.080
R(reflections)= 0.0382( 9611) wR2(reflections)= 0.0828( 13202)
S = 1.015 Npar= 941

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level C PLAT220_ALERT_2_C NonSolvent Resd 1 F Ueq(max)/Ueq(min) Range 3.9 Ratio PLAT911_ALERT_3_C Missing FCF Refl Between Thmin & STh/L= 0.600 6 Report -8 4 16, -8 4 17, -8 5 17, -8 4 18, -9 5 18, -9 6 18,
Alert level G PLAT002_ALERT_2_G Number of Distance or Angle Restraints on AtSite 1 Note PLAT003_ALERT_2_G Number of Uiso or U(i,j) Restrained non-H-Atoms 1 Report PLAT154_ALERT_1_G The s.u.'s on the Cell Angles are Equal ..(Note) 0.003 Degree PLAT172_ALERT_4_G The CIF-Embedded .res File Contains DFIX Records 1 Report PLAT186_ALERT_4_G The CIF-Embedded .res File Contains ISOR Records 1 Report PLAT242_ALERT_2_G Low MainResAtom Ueq as Compared to Neighbours C24 Check PLAT794_ALERT_5_G Tentative Bond Valency for Y1 (III) . 3.39 Info PLAT794_ALERT_5_G Tentative Bond Valency for Y2 (III) . 3.37 Info PLAT860_ALERT_3_G Number of Least-Squares Restraints ............. 7 Note PLAT910_ALERT_3_G Missing FCF Reflection(s) Below Theta(Min)[Deg]= 1.55 Note 0 1 0, 0 0 1, PLAT912_ALERT_4_G Missing # of FCF Reflections Above STh/L= 0.600 62 Note PLAT969_ALERT_5_G The 'Henn et al.' R-Factor-gap value ........... 2.079 Note Predicted wR2: Based on SigI**2 3.99 or SHELX Weight 8.15 Note PLAT978_ALERT_2_G Number C-C Bonds with Positive Residual Density. 6 Info
0 ALERT level A = Most likely a serious problem - resolve or explain 0 ALERT level B = A potentially serious problem, consider carefully 2 ALERT level C = Check. Ensure it is not caused by an omission or oversight 13 ALERT level G = General information/check it is not something unexpected 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 5 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 3 ALERT type 4 Improvement, methodology, query or suggestion 3 ALERT type 5 Informative message, check


Publication of your CIF

You should attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the nature of your study may justify the reported deviations from journal submission requirements and the more serious of these should be commented upon in the discussion or experimental section of a paper or in the "special_details" fields of the CIF. checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts that are not important in a particular case may appear. Conversely, the absence of alerts does not guarantee there are no aspects of the results needing attention. It is up to the individual to critically assess their own results and, if necessary, seek expert advice.

If you wish to submit your CIF for publication in Acta Crystallographica Section C or E, you should upload your CIF via the web. If you wish to submit your CIF for publication in IUCrData you should upload your CIF via the web. If your CIF is to form part of a submission to another IUCr journal, you will be asked, either during electronic submission or by the Co-editor handling your paper, to upload your CIF via our web site.


PLATON version of 23/04/2026; check.def file version of 30/03/2026
Datablock AC_0004Y - ellipsoid plot

Download CIF editor (publCIF) from the IUCr
Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry